搜索

PPC series air box pulse bag dust collector

Product consultation telephone:13962923000
PPC series air box pulse bag dust collector
Product Introduction

1. Overview

PPC air box pulse bag filter is a new and efficient bag filter developed by our company on the basis of digesting and absorbing foreign advanced technology and combining with my country's national conditions. It integrates the advantages of sub-chamber back-blowing and jet pulse bag filter, and overcomes the lack of kinetic energy for cleaning the back-blowing of the compartment. The simultaneous cleaning and filtering of the jet pulse will produce the defects of secondary dust adsorption. The efficient off-line dust removal method has the characteristics of large dust removal energy, good dust removal effect, low system resistance, long service life of the filter bag, and high dust removal efficiency. It is widely used in dust purification in various industries such as building materials, metallurgy, electric power, and chemical industries.

This series of dust collectors are composed of different numbers of chambers and different filter bags in each chamber to form a variety of different specifications. There are 32, 64, 96, and 128 filter bags in each chamber. The filter bag diameter is Φ130mm. The length of the filter bag is 2450mm and 3060mm.

 

2. Performance characteristics

1. Offline pulse dust removal, dust removal efficiency is as high as 99.9% or more, dust has no secondary adsorption, especially suitable for processing high-concentration flue gas.

2. Using high-temperature flue gas to blow back, effectively prevent condensation and bagging

3. The use of a new type of easy-to-clean filter material and a reliable flue gas temperature tracking system can adapt to various flue gas conditions.

4. Fully automatic computer control, easy operation and good reliability.

5. The air box structure reduces local resistance and eliminates the inconvenience of installing the filter bag.

 

PPC32 technical performance parameter table

Specification model PPC32-3 PPC32-4 PPC32-5 PPC32-6 PPC64-4 PPC64-5 PPC64-6 PPC64-7 PPC64-8
Handling air volume(m³/h) 4464 5952 7440 8928 11904 14880 17856 20832 23808
Total filtration area(m²) 93 124 155 186 248 310 372 434 496
Number of dust collection rooms(A) 3 4 5 6 4 5 6 7 8
Number of bags per room (pieces) 32 64
Total number of filter bags (strip) 96 128 160 192 256 320 384 448 512
Pulse valve Quantity(A) 3 4 5 6 4 5 6 7 8
Specification (inch)
Filter bag specifications(mm×mm) Φ133x2450
Filter bag material Select according to the nature of the flue gas
Filter wind speed(m/min) 0.7-0.9 (Select different purification and filtration wind speeds according to different processes)
Bear negative pressure(Pa) ≤6000
Dust collector resistance(Pa) 1470-1770
Inlet gas dust concentration(g/Nm³) <200 <1000
Blowing pressure(MPa) 0.5-0.7
Compressed air consumption(m³/min) 0.27 0.37 0.46 0.55 1.2 1.5 1.8 2.1 2.4
Wind ballast According to the process needs to be determined
Screw conveyor no According to the process needs to be determined
Insulation area(m²) 26.5 34 41 48.5 70 94 118 142 176

 

PPC96 technical performance parameter table

Technical parameters/specifications PPC96-4 PP96-5 PPC96-6 PPC96-7 PPC96-8 PPC96-9 PPC96-10 PPC96-12 PPC96-14 PPC96-16 PPC96-18 PPC96-20
Handling air volume(m³/h) 17856 22320 26736 31200 35712 40128 44640 49104 58032 66960 75888 84816
Total filtration area (m²) 372 465 557 650 744 836 930 1023 1209 1395 1581 1767
Number of dust collection rooms (A) 4 5 6 7 8 9 10 12 14 16 18 20
Number of bags per room (pieces) 96
Total number of filter bags (strip) 384 480 576 672 768 864 960 1152 1344 1536 1728 1920
Pulse valve Quantity(A) 4 5 6 7 8 9 10 12 14 16 18 20
Specification (inch) 3"
Filter bag specifications(mm×mm) Φ133x2450
Filter bag material Select according to the nature of the flue gas
Filter wind speed (m/min) 0.7-0.9 (Select different purification and filtration wind speeds according to different processes)
Withstand negative pressure (Pa) ≤6000
Resistance of dust collector (Pa) 1470-1770
Dust concentration of inlet gas (g/Nm³) <1300
Blowing pressure(MPa) 0.5-0.7
Compressed air consumption(m³/min) 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.4 4.2 4.8 5.4 6.0
Wind ballast According to the process needs to be determined
Screw conveyor According to the process needs to be determined
Insulation area (m²) 110 120 130 140 150 160 175 210 215 280 315 350

Note: 1. The processed air volume in the table refers to the factory air supply. If a separate air compressor is installed, the air consumption in the table should be multiplied by a factor of 1.3.

2. The processing air volume in the table refers to the calculation when the filter wind speed is 0.8m/min. It is only for the user when the dust concentration at the dust source point is less than 200g/Nm3 and the net filter wind speed is unknown. For selection.

3. The heat preservation area in the table is for reference only and can be determined according to user requirements.

 

PPC128 technical performance parameter table

Technical parameters/specifications PPC128-6 PPC128-7 PPC128-8 PPC128-9 PPC128-10 PPC128-12 PPC128-14 PPC128-16 PPC128-18 PPC128-20 PPC128-22 PPC128-24 PPC128-26 PPC128-22
Handling air volume(m³/h) 44928 52416 59904 67392 74784 89856 104832 119808 134784 149760 164736 179712 194400 209328
Total filtration area (m²) 936 1092 1248 1404 1558 1872 2184 2496 2808 3120 3432 3744 4050 4361
Number of dust collection rooms (A) 6 7 8 9 10 12 14 16 18 20 22 24 26 28
Number of bags per room (pieces) 128
Total number of filter bags (strip) 768 896 1024 1152 1280 1536 1792 2048 2304 2560 2816 3072 3328 3584
Pulse valve Quantity(A) 12 14 16 18 20 24 28 32 36 40 44 48 52 56
Specification (inch) 3"

Filter bag specifications(mm×mm)

Φ133x3060
Filter bag material Select according to the nature of the flue gas
Filter wind speed (m/min) 0.7-0.9 (Select different purification and filtration wind speeds according to different processes)
Withstand negative pressure (Pa) ≤6000
Resistance of dust collector (Pa) 1470-1770
Dust concentration of inlet gas (g/Nm³) <1300
Blowing pressure(MPa) 0.5-0.7
Compressed air consumption(m³/min) 3.5 4.2 4.8 5.4 6.0 7.0 8.3 9.5 10.7 12 13.1 14.3 15.5 16.7
Wind ballast According to the process needs to be determined
Screw conveyor According to the process needs to be determined
Insulation area (m²) 116 124 131 139 147 232 247 262 277 292 307 322 337 352

Note: 1. The processed air volume in the table refers to the factory air supply. If a separate air compressor is installed, the air consumption in the table should be multiplied by a factor of 1.3.

2. The processing air volume in the table refers to the calculation when the filter wind speed is 0.8m/min. It is only for the user when the dust concentration at the dust source point is less than 200g/Nm3 and the net filter wind speed is unknown. For selection.

3. The heat preservation area in the table is for reference only and can be determined according to user requirements

There is currently no content to display
Please add data record on website background.
Free Product Quotation
Our staff will contact you within 24 hours (weekdays), if you need other services,Welcome to call the service hotline:13962923000
全部评论
已有0条评论
There is currently no content to display
Please add data record on website background.

Nantong Lingzhi Environmental Protection Technology Co., Ltd

Service Hotline: 

Address:

Chengbei Industrial Park, Hai'an City, Nantong City, Jiangsu Province

Copyright:Nantong Lingzhi Environmental Protection Technology Co., Ltd    苏ICP备17049804号-1